MultiPlus-II 12V/4k 160-50 2x120V 50/60Hz Inverter/Charger
120/240 V input output, or 120 V input and output (Always 120 V output when in inverter mode)
The AC input can be supplied from a split-phase 120/240 V source, or a single-phase 120 V source. When an AC source is available, the MultiPlus will feed through the AC to its output. The output will therefore mirror the AC input. The inverter/charger connects to the neutral and the preferred input line (L1). Power needed to charge the batteries will therefore be drawn from L1. The MultiPlus switches to inverter operation when no AC source is available. The inverter output is 120 V single-phase. In inverter mode, the MultiPlus connects both output lines (L1 and L2) to provide 120 VAC to loads on either line. Any 240 V loads will therefore be supplied only when the MultiPlus is supplied by a split-phase AC source. This prevents heavy loads such as water heaters or 240 V air conditioners from discharging the battery.
PowerControl PowerAssist - Boosting the capacity of the grid or a generator
A maximum grid or generator current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl function). PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery. When the load reduces, the spare power is used to recharge the battery (available on L1 input only).
Two AC Outputs
The main output has no break functionality. The MultiPlus takes over the supply to the connected 120 V loads in the event of a grid failure or when shore/generator power is disconnected. The transfer time of the L1 output is less than 18 milliseconds so that computers and other electronic equipment will continue to operate without disruption. The transfer time of the L2 output is longer: approximately 40 milliseconds. The second (auxiliary) output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery can be connected to this output.
Virtually unlimited power thanks to parallel and three phase operation
Up to 6 Multis can operate in parallel to achieve higher power output. In addition to parallel connection, three units of the same model can be configured for three phase output. In multi-phase setups, L2 is disabled on all units.
On-site system configuring, monitoring control
Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface needed). Several monitoring and control options are available: Cerbo GX, Ekrano GX, laptop, computer, Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.
Remote configuring monitoring
Install a Cerbo GX or other GX product to connect to the internet. Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge. When connected to the internet, systems can be accessed remotely, and settings can be changed.
Please contact your dealer for any returns, repairs or support issues related to this product.The Victron Energy MultiPlus-II 12V/4k 160-50 2x120V 50/60Hz Inverter/Charger PMP122405210 supports split-phase 120/240V AC input and output, or single-phase 120V input and output. When AC power is available, the unit passes the input through to the output. When operating in inverter mode, it provides 120V single-phase output to loads on either output line.
PowerControl helps prevent a grid or generator from being overloaded by accounting for other AC loads and directing available capacity toward battery charging. PowerAssist supplements insufficient shore, generator, or grid power with battery power during temporary demand peaks, then uses available excess power to recharge the battery when the load decreases. PowerAssist is available on the L1 input only.
The MultiPlus-II includes two AC outputs. The main output takes over connected 120V loads during a grid failure or loss of shore or generator power, with an L1 transfer time of less than 18 milliseconds. The auxiliary output is active only when AC input is available, allowing loads that should not discharge the battery to be connected separately.
Up to six units can operate in parallel for increased power output, and three units of the same model can be configured for three-phase output. System settings can be adjusted using VEConfigure software with a computer or laptop and MK3-USB interface. Monitoring and control options include Cerbo GX, Ekrano GX, a computer, Bluetooth with the optional VE.Bus Smart dongle, a Battery Monitor, and the Digital Multi Control Panel. A Cerbo GX or other GX product can also enable internet connectivity, VRM data access, remote monitoring, and remote setting changes.
Features:
- AC Input and Output: Supports split-phase 120/240V AC or single-phase 120V AC operation; inverter mode provides 120V output.
- PowerControl: Helps prevent generator or grid overload by managing available AC capacity for battery charging.
- PowerAssist: Supplements temporary peak demand with battery power and recharges the battery when load demand decreases.
- Two AC Outputs: The main output supports automatic transfer during AC power loss, while the auxiliary output is live only when AC input is available.
- Parallel Operation: Up to six MultiPlus units can operate in parallel for higher power output.
- Three-Phase Configuration: Three units of the same model can be configured for three-phase output.
- System Configuration: Settings can be changed with VEConfigure software, a computer or laptop, and an MK3-USB interface.
- Monitoring and Control: Compatible monitoring and control options include Cerbo GX, Ekrano GX, computers, Bluetooth with the optional VE.Bus Smart dongle, a Battery Monitor, and the Digital Multi Control Panel.
- Remote Management: A Cerbo GX or other GX product can connect the system to the internet for VRM data access, remote monitoring, and remote setting changes.